-40%

5V Volt DC Precision Reference Voltage Standard 5.0000v

$ 42.24

Availability: 100 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • All returns accepted: Returns Accepted
  • Brand: Unbranded
  • Condition: New
  • Return shipping will be paid by: Buyer
  • Restocking Fee: No
  • Item must be returned within: 14 Days
  • MPN: Does Not Apply

    Description

    This device can be used to check the calibration of your DVM or DMM.  The output is 5V and conservatively rated to be accurate within 0.001% (+/- 50uV) when new and within +/-100uV for a minimum of 6 months at room temperature between 65
    º
    F to 90
    º
    F. Initial value was nulled (+/- 10uV) to a calibrated Fluke 332B voltage standard and verified by a calibrated Agilent Keysight 34461A.
    This Fluke 332b voltage standard was nulled to Fluke 5520A calibrator and verified by a Fluke 8508A (+6uV) in local ISO/IEC 17025:2017 accredited electronics calibration shop.
    In order to reach the designed accuracy, thermal equilibrium of the internal electronics is required. Please turn the device on in a constant temperature environment at least 2 hours before taking any measurement.
    The circuit is based on the LT12021-5 which uses buried Zener technology which has excellent long term stability.
    Temperature compensation circuit
    included in this device.  this device
    has been tested in 20ºC, 25
    ºC &
    30
    ºC
    chamber and
    temperature coefficient
    result shows equal or better than +/-1.5 ppm/ºC.
    There is a power status LED. LED lit green indicates sufficient voltage for proper operation. If the input voltage is too low, the LED will turn red and cut off output voltage when unable to perform within specification.
    This voltage standard is built using aluminum casing with better durability and better electromagnetic shielding for increased voltage output stability.
    Final adjustment perform in
    25
    ºC incubator
    after aged for 800+ hours in room temperature and/or 156 hours in 125
    ºC aging oven
    .
    The device is powered by an external DC power supply from 9V to 12V. A linear power supply is recommended. DO NOT SUPPLY OVER 20 V.
    Unlimited recalibration service is free for the first three years after purchase- just mail it back to us with .00 for USPS First class return shipping charge within the USA.
    If there is manufacturing defect or loss of calibration within the first three years. Ship it back to us with return shipping cost of .00 and we will fix it or send you another one free of charge.