-40%
Fluke 5320A Multifunction Electrical Tester Calibrator w/ HV Adapter / R Multi
$ 10559.47
- Description
- Size Guide
Description
What's included:Fluke 5320A
Fluke 5320A HV Adapter / R Multiplier
Nothing else is included, no other accessories are included aside from 2 items listed above.
One corner is physically damaged however it does not seem to effect electronic
performance
at all. Buttons and screen is in good shape, additional screen protector was added onto the unit that can easily be removed. Minor wear around the outer casing.
Passes self-test and basic test with a DMM.
This is *not* the 5320A/VLC model and so does not include the following functions:
AC/DC Voltage Calibrator (5320A/VLC only)
Correction COMP Mode (Active Loop Compensation) (5320A/VLC only)
Leakage Current Source Active Mode (5320A/VLC only)
Note: Shipping cost **does not**, this would be extra based on the high-ticket costs for this item.
From Fluke's Specification Sheet:
General Specifications
Warm-Up Time
.........................................................30 minutes
Specifications Confidence Level
..........................99 %
Specifications Interval
............................................1 year
Temperature Performance
Operating Temperature ........................................18 to 28
°
C
Calibration Temperature (tcal) ............................23
°
C
Temperature Coefficient.......................................Temperature coefficient for temperature outside of Tcal
±
5
°
C between
+5
°
C to +40
°
C is 0.1 x /
°
C Storage Temperature ............................................-20 to +70
°
C
Relative Humidity (operating)
..............................<70 % to 28
°
C
Altitude
Operating................................................................3,050 m (10,000 ft.)
Storage....................................................................12,200 m (40,000 ft.)
Dimensions
................................................................450 mm X 480 mm X 170 mm (17.7 in. X 18.9 in. X 6.7 in.)
Weight
........................................................................18 kg (39.7 lb)
Power Line
.................................................................115/230 V ac (50/60 Hz)
±
10 %, with the maximum voltage difference
between Neutral and Protective Earth not exceeding 20 V.
Power Consumption
................................................150 VA Maximum
Safety Class
...............................................................Class I, Bonded Enclosure
Electrostatic Discharge
..........................................This instrument meets class I for ESD requirements per EN 61326
(Criteria A)
W
Fuse Protection
AC mains input ......................................................2 A, 250 V for 230 V, Time delay (T2L250 V – 5 x 20 mm)
4 A, 250 V for 115 V, Time delay (T4L250 V – 5 x 20 mm) RCD input ...............................................................3.15 A, 250 V, Fast (F3.15L250V – 5 x 20 mm)
Meter amps (A) input............................................20 A, 500 V, Time delay (T20L500V – 6.3 x 32 mm) Loop/Line impedance input.................................4 A, 250 V, Time delay (T4L250V – 6.3 x 32 mm) Leakage current input ..........................................100 mA, 150V, Fast (F100mL150V – 5 x 20 mm)
Low Resistance Source
Total Range
...............................................................100 m
Ω
to 10 k
Ω
Resolution
..................................................................31⁄2 digits (continuously variable)
Electrical Specifications
Uncertainty and Maximum Ratings
Range
100 m
Ω
to 4.99
Ω
5 to 29.9
Ω
30 to 199.9
Ω
200 to 499
Ω
500
Ω
to 1.999 k
Ω
2 to 4.99 k
Ω
5 to 10 k
Ω
Resolution
0.1 m
Ω
0.01
Ω
0.1
Ω
1
Ω
1
Ω
10
Ω
10
Ω
Maximum AC or DC Current
[1]
400 mA 250 mA 100 mA 45 mA 25 mA 10 mA 5 mA
2-Wire Uncertainty
[2]
(tcal
±
5
°
C)
0.3 % + 25 m
Ω
0.2 % + 25 m
Ω
0.2 % + 25 m
Ω
0.2 %
0.2 % 0.2 % 0.2 %
4-Wire Uncertainty (tcal
±
5
°
C)
0.3 % + 10 m
Ω
0.2 % + 10 m
Ω
0.2 % + 10 m
Ω
0.2 %
0.2 % 0.2 % 0.2 %
orporation
5320A Multifunction Electrical Tester Calibrator
Notes:
[1] Test current can exceed 120 % of maximum current for up to 3 seconds. Terminals automatically disconnect if test current exceeds
120 % of specified maximum current.
[2] Uncertainty is valid to 200 mW. For higher power rating, add 0.1 % per each 300 mW above 200 mW.
Test Current Measurement
Range
..........................................................................0 to 400 mA ac + dc rms
Resolution
..................................................................1 mA
Uncertainty
................................................................
⎛
⎛
20
⎞
⎞
R = set resistance between 0.5
Ω
to 10 k
Ω
.
⎜⎜ ⎟ +
0.1
⎟
mA
⎝
⎝
R
⎠
⎠
Nominal resistance
.................................................<50 m
Ω
Maximum current
....................................................400 mA ac + dc rms
Open Mode
Nominal resistance
.................................................30 M
Ω ±
20 %
Maximum input voltage allowed
.........................50 V ac + dc rms
Test voltage reading
...............................................0 to 50 V ac + dc rms
Resolution
..................................................................1 V
Uncertainty
................................................................5 % + 2 V
High Resistance Source
Range
..........................................................................10 k
Ω
to 10 G
Ω
plus 100 G
Ω
single value selection.
Resolution
..................................................................41⁄2 Digit (continuously variable for 10 k
Ω
to 10 G
Ω
range)
Uncertainty and Maximum Ratings
Range
10.000 to 39.99 k
Ω
40.00 to 99.99 k
Ω
100.00 to 199.99 k
Ω
200.0 to 999.9 k
Ω
1.0000 to 9.999 M
Ω
10.000 to 999.9 M
Ω
1.0000 to 10.000 G
Ω
100 G
Ω
Resolution
1
Ω
10
Ω
10
Ω
100
Ω
100
Ω
1 k
Ω
100 k
Ω
NA
Maximum Voltage (ac + dc) Peak
55 V 400 V 800 V 1100 V 1150 V 1575 V
[2]
1575 V
[2]
1575 V
[2]
Uncertainty
[1]
(tcal
±
5
°
C)
0.2 % 0.2 % 0.2 % 0.2 % 0.3 % 0.5 % 1.0 % 3.0 %
[3]
Notes:
[1] Uncertainty is valid to 500 volts. For test voltages above 500 V, add 0.1% for each 200 V above 500 V.
[2] Maximum test voltage with the supplied banana leads is 1000 Vrms. For higher voltages, use leads rated at 1575 V or above.
[3] Calibration value uncertainty is specified in the table. Nominal value is
±
15 %.
Test Voltage Measurement
Range
..........................................................................0 to 2000 V dc peak
Resolution
..................................................................1 V
Uncertainty
................................................................1 % + 5 V for R above 1 M
Ω
1 % + 2 V for R below 1 M
Ω
Settling Time
............................................................2 seconds for input deviations of <5 %
Test Current Measurement
Range
..........................................................................0 to 9.9 mA dc
Uncertainty
................................................................1.5 % + 5V/R A (where R is the selected resistance value)
Settling time
..............................................................2 seconds (for voltage reading deviations < 5 %)
Short Mode
Nominal resistance
.................................................<100
Ω
Maximum input current allowed
.........................50 mA ac + dc rms
Test current range
...................................................0 to 50 mA ac + dc rms
Resolution
..................................................................0.1 mA
Uncertainty
................................................................2 % + 0.5 mA
Resistance Multiplier Adapter (x1000 multiplier)
Resistance range
.....................................................350 M
Ω
to 10 T
Ω
Range
350.0 M
Ω
to 99.99 G
Ω
100.00 G
Ω
to 999.9 G
Ω
1.0000 T
Ω
to 10.000 T
Ω
Resolution
100 k
Ω
10 M
Ω
100 M
Ω
Maximum Voltage (ac + dc) Peak
10000 V 10000 V 10000 V
Uncertainty (tcal
±
5
°
C)
1.0%+R
[1]
2.0%+R
[1]
3.0%+R
[1]
Uncertainty and Maximum Ratings
Notes:
[1] R is the uncertainty of resistor to be multiplied by 1000.
Ground Bond Resistance Source
Resistance Mode
Range
..........................................................................25 m
Ω
to 1.8 k
Ω
Resolution
..................................................................16 discrete values
Minimum test voltage/current
..............................10 V / 10 mA
Test Current Measurement Range
.......................0 to 40 A ac + dc rms
Test Current Measurement Resolution
...............1 mA to 100 mA depending on resistance output and test current
Uncertainty and Maximum Ratings
Nominal Value
25 m
Ω
50 m
Ω
100 m
Ω
330 m
Ω
500 m
Ω
1
Ω
1.8
Ω
5
Ω
10
Ω
18
Ω
50
Ω
100
Ω
180
Ω
500
Ω
1 k
Ω
1.8 k
Ω
Deviation from Nominal Value
±
50 %
±
50 %
±
30 %
±
20 %
±
10 %
±
10 %
±
10 %
±
10 %
±
10 %
±
10 %
±
10 %
±
10 %
±
10 %
±
10 %
±
10 %
±
10 %
Absolute Uncertainty of Characterized Value (tcal
±
5
°
C)
±
5 m
Ω ±
5 m
Ω ±
5 m
Ω
±
7 m
Ω
±
8 m
Ω ±
10 m
Ω ±
18 m
Ω ±
30 m
Ω ±
60 m
Ω ±
100 m
Ω ±
300 m
Ω ±
500 m
Ω ±
1
Ω ±
2.5
Ω ±
5
Ω ±
10
Ω
Maximum Continuous Test
Current
[1]
ACrms or DC
30 A 28 A 25 A 14 A 10 A 8A
6 A 3.2 A 2.0 A 1.5 A 0.8 A 0.5 A 0.25 A 0.1 A 0.05 A 0.025 A
Maximum Short- term Test Current AC rms or DC
[2]
40A 40A 40A 40A 40A 40A 30A 21A 15A 10 A 5.0 A 3.0 A 1.35 A 0.6 A 0.3 A 0.15 A
Test Current Uncertainty
1.5 % + 0.7 A
1.5 % + 0.5 A 1.5 % + 0.35 A 1.5 % + 0.3 A 1.5 % + 0.2 A 1.5 % + 150 mA 1.5 % + 100 mA 1.5 % + 70 mA 1.5%+50mA 1.5%+30mA 1.5%+20mA 1.5%+10mA 1.5 % + 5 mA
1.5%+3 1.5%+2 1.5%+2
mA mA mA
Notes:
[1] Test currents up to 30 % of maximum continuous test current can be applied to the Calibrator with no time limitation. Test
current between 30 % and 100 % of the maximum continuous test current can be applied to the Calibrator for a limited time. Minimum period of full current load is 45 seconds. The Calibrator calculates the allowed time period and when exceeded, the output connectors are disconnected.
[2] Maximum short term test current is defined as the rms value of halfwave or fullwave test current flowing through the UUT. Maximum time of test is 200 ms. A time interval of 200 ms represents 10 full waves of power line voltage at 50 Hz and 12 full waves at 60 Hz.
Open Mode
Nominal resistance
.................................................>100 k
Ω
Maximum voltage
....................................................50 V ac + dc rms
Test voltage range
...................................................0 to 50 V ac + dc rms
Resolution
..................................................................1 V
Uncertainty
................................................................2 % + 2 V
Transfer Ground Bond Resistance Accuracy in m
Ω
UUT Test Current
Transfer Mode
Transfer GBR
Marking
(m
Ω
)
on
Display
30 A
±
0.8 m
Ω ±
0.9 m
Ω
-
-
28 A
±
0.8 m
Ω
±
1.0 m
Ω ±
1.1 m
Ω
-
25 A
±
0.8 m
Ω
±
1.0 m
Ω ±
1.1 m
Ω ±
1.4 m
Ω
20 A
±
0.9 m
Ω
±
1.0 m
Ω ±
1.2 m
Ω ±
1.4 m
Ω
14 A
±
1.0 m
Ω
±
1.2 m
Ω ±
1.3 m
Ω ±
1.6 m
Ω ±
3.0 m
Ω
8A
±
1.3 m
Ω
±
1.5 m
Ω
±
1.7 m
Ω
±
2.0 m
Ω
±
3.6 m
Ω ±
4.1m
Ω±
4.4m
Ω±
7.2m
Ω
50 0
80 R1 120 R2 170 R3 420 R4 550 R5
10 A
±
1.2 m
Ω
3 A
±
2.6 m
Ω ±
2.9 m
Ω ±
3.1 m
Ω ±
3.6 m
Ω ±
6.0 m
Ω
----
- - - - -
±
1.4 m
Ω ±
1.5 m
Ω ±
1.8 m
Ω ±
3.3 m
Ω
Maximum and Minimum Applicable Test Currents from the Ground Bond Resistance Meter
5320A Transfer GBR (m
Ω
) UUT Minimum Test Current AC/DC (A) UUT Maximum Test Current AC/DC (A)
50 3 30
80 3 30 120 3 28 170 3 25 420 3 14 550 3 10
Notes
The minimum value of the indicated test current is 0.05 A.
The transfer GBR indication as the main value on the display is shown when the test current is 3 A or greater.
Line/Loop Impedance Source
Range
..........................................................................25 m
Ω
to 1.8 k
Ω
Resolution
..................................................................16 discrete values
Minimum test voltage/current
..............................10 V/10 mA
Test Current Measurement
Type of recognized test current
...........................Positive impulse (halfwave), negative impulse (halfwave), symmetrical
(fullwave).
Range
..........................................................................0 to 40 A ac + dc rms
Resolution
..................................................................1 to 100 mA depending on test current and resistance output
Prospective Fault Current
Range
..........................................................................0 to 10 kA
Correction Manual Mode
Residual Impedance Range
...................................0 to 10
Ω
Resolution
..................................................................1 m
Ω
Uncertainty
................................................................Uncertainty in manual (MAN) mode is the uncertainty of selected
resistance value. See table above. Also, the uncertainty of the manually entered correction should be taken into consideration.
Correction Scan Mode
Residual Impedance Range
...................................0 to 10
Ω
Resolution
..................................................................1 m
Ω
Uncertainty
................................................................(1 % +15 m
Ω
) + uncertainty of selected resistance value.
Leakage Current Source
Range
..........................................................................0.1 to 30 mA
Resolution:
Passive Mode .........................................................10
μ
A setting, 1
μ
A measurement Differential Mode...................................................10
μ
A setting, 1
μ
A measurement Substitute Mode.....................................................10
μ
A
Active Mode (5320A/VLC only)...........................10
μ
A
Test Voltage:
Passive Mode .........................................................60 to 250 V ac + dc rms Differential Mode...................................................60 to 250 V ac + dc rms Substitute Mode.....................................................10 to 250 V ac + dc rms Active Mode (5320A/VLC only)...........................50 to 100 V ac + dc rms
Uncertainty:
Passive Mode .........................................................0.3 % + 2
μ
A ac + dc rms Differential Mode...................................................0.3 % + 2
μ
A ac + dc rms
Test uncertainty can be influenced by power line voltage instability Substitute Mode.....................................................0.3 % + 2
μ
A ac + dc rms
Active Mode (5320A/VLC only)...........................0.3 % + 1
μ
A ac + dc rms
RCD (Residual Current Device)
Trip Current Range
:
0.5 X I and 1 X I Mode..........................................3 to 3000 mA in 1 mA steps 1.4 X I and 2 X I Mode..........................................3 to 1500 mA in 1 mA steps 5 X I Mode ..............................................................3 to 600 mA in 1 mA steps
Trip Current Measurement Resolution
...............1
μ
A on 30 mA range 10
μ
A on 300 mA range
100
μ
A on 3A range
Uncertainty
:
0.5 X I and 1 X I Mode..........................................1 % rms 1.4 X I and 2 X I Mode..........................................2 % rms 5 X I Mode ..............................................................5 % rms
Trip Time Range
......................................................10 to 5000 ms
Trip Time Uncertainty
............................................0.02 % + 0.25 ms
Series Resistance
.....................................................0.025
Ω
, 0.05
Ω
, 0.1
Ω
, 0.33
Ω
, 0.5
Ω
, 1
Ω
, 1.8
Ω
, 5
Ω
, 10
Ω
, 18
Ω
,
50
Ω
, 100
Ω
, 180
Ω
, 500
Ω
, 1000
Ω
, 1800
Ω
Line/Touch Voltage Range
....................................250 V
Line/Touch Voltage Uncertainty
..........................5 % + 3 V
Multimeter
Voltage
Range
..........................................................................0 to 1100 V ac rms or dc
Resolution
..................................................................41⁄2 digits
Internal Ranges
........................................................10, 100, and 1100 V (Autoranging only)
Frequency Range
.....................................................DC, 20 Hz to 2 kHz
Input Resistance
......................................................10 M
Ω ±
1 %
Time Constant
..........................................................1.5 s
Readings/Second
.....................................................2
Measurement Category
..........................................1000 V CAT I, 300 V CAT II
Range
10 V 100 V 1100 V
AC/DC Voltage Uncertainty Resolution
0.001 V 0.01 V 0.1 V
Uncertainty
±
(% of Reading + mV)
0.15 % + 5 0.20 % + 50 0.20 % + 550
Current
Range
..........................................................................0 to 20 A continuous, 30 A for up to 30 minutes, ac rms or dc
Resolution
..................................................................41⁄2 digits
Internal Ranges
........................................................300 mA, 3 and 30 A (Autoranging only)
Frequency Range
.....................................................DC, 20 to 400 Hz
Time Constant
..........................................................1.5 s
Readings/Second
.....................................................2
Range
300 mA 3 A 30 A
AC/DC Current Uncertainty Resolution
0.1 mA 1 mA 10 mA
Uncertainty
±
(% of Reading + mV)
0.15 % + 0.15 0.15 % + 1.5 0.30 % + 15
Hipot Leakage Current Measurement Mode
Range
..........................................................................0 to 300 mA ac rms or dc
Resolution
..................................................................4 1/2 digits
Frequency range
......................................................DC, 20 Hz to 400 Hz
Time constant
...........................................................1.5 s
Readings/second
.....................................................2
Phantom Power
Range
..........................................................................0 to 33 kVA
Resolution
..................................................................3 digits
Uncertainty
................................................................
2 2
where V
unc
is specified uncertainty of measured voltage and I
unc
is specified uncertainty of measured current.
Range
300 uA 3 mA 30 mA 300 mA
Resolution
0.01
μ
A 0.1
μ
A 1
μ
A 10
μ
A
Uncertainty
±
(% of reading +
μ
A)
0.3 % + 0.21
0.2 % + 1.5
0.2 % + 15
0.2 % + 150
(
V
unc
)
+
(
I
unc
)
Hipot Leakage Current Mode Uncertainty
Hipot Timer Measurement Mode
Range
..........................................................................0.1 to 999 s
Resolution
..................................................................1 ms
Uncertainty
................................................................0.02 % + 2 ms (dc)
0.02 % + 20 ms (ac)
10 kV Adapter (1000:1 voltage divider)
Range
..........................................................................0 to 10 kV ac peak/dc
Resolution
..................................................................41⁄2 digits
Uncertainty
................................................................0.3 % of value + 5 V dc
0.5 % of value + 5 V ac at 50 or 60 Hz
80K-40 High Voltage Probe
Range
..........................................................................0 to 40 kV ac peak/dc
Resolution
..................................................................41⁄2 digits
Uncertainty
................................................................0.5 % of value + 10 V dc
0.5 % of value + 10 V ac at 50 or 60 Hz