Fluke Calibration 9103-D-156 Field Dry-Well Temperature Calibrator
$ 2170.31
- Description
- Size Guide
Description
Subscribe to Our NewsletterFluke Calibration 9103-D-156 Field Dry-Well Temperature Calibrator with Model 3103-6 ("D" Insert), -25 °C to 140 °C
Brand:
Fluke Calibration
Model No:
9103-D-156
Ref No:
2001126
Our Model No:
9103D156
Product Overview
Features
Lightweight and very portable
Accuracy to ± 0.25 °C
RS-232 and Interface-it software included
Interchangeable inserts
Goes as low as -25 °C
Convenient handle
Universal AC input
Temperature scan rate control
Temperature switch hold
Eight set-point memory
Adjustable readout in °C or °F
3103-6
Six miscellaneous holes
Hole quantities and sizes: 2 Holes, 3 mm; 2 Holes, 4 mm; 2 Holes, 6 mm
Removable inserts sized for probes with named diameter
Use additional inserts to broaden range of hole sizes available
For use with Models 9011 and 9103
Description
The Fluke Calibration 9103D156 Field Dry-Well Temperature Calibrator with Model 3103-6 ("D" Insert), -25 °C to 140 °C may be used as a portable instrument or bench top temperature calibrator for calibration thermocouples and RTD temperature probes. The 9103-D-156 is small enough to use in the field and accurate enough to use in the lab. With an ambient temperature of 23°C (74°F), calibrations may be done over a range of –25°C to 140°C (–13°F to 284°F). The resolution of the 9103-D-156 temperature display is 0.1 degrees.
The temperature is accurately controlled by Hart’s hybrid analog/digital controller. The controller uses a precision platinum RTD as a sensor and controls the well temperature with pulsed driven Thermal Electric Devices (TED).
The LED display panel continuously shows the current well temperature. The temperature may be easily set with the control buttons to any desired temperature within the specified range. The calibrator’s multiple fault protection devices insure user and instrument safety and protection.
The 9103-D-156 Dry-well was designed for portability, low cost, and ease of operation. Through proper use, the instrument will continuously provide accurate calibration of temperature sensors and devices. The user should be familiar with the safety guidelines and operating procedures of the calibrator as described in this user manual.
Included Components
1 - "D" Insert
1 - Power Cord
1 - Insert Removal Tool
1 - 9930 Interface-it Software
1 - Serial Cable
1 - User Manual
Terms & Conditions
Please note estimated delivery time above. Contact us for details or if you have a delivery requirement. We ask for your patience while striving to ensure your shipment arrives quickly and accurately.
Domestic Shipping
FREE Standard Shipping on items OVER and less than 30lbs to continental U.S. Add for AK, HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands, Guam, Puerto Rico, U.S. Virgin Islands and American Samoa.
PO Boxes/APOs require USPS shipping and may therefore experience longer lead times
6.25% Sales Tax for shipping to MA
International Shipping
Due to international voltage requirements, please ask us prior to purchasing to confirm your product will operate correctly in your country.
Please contact us for shipping rates to any overseas U.S. territories.
International customers are responsible for all shipping charges, including any duties or taxes.